| LED Status (Red/Green) | Error Description | Likely Cause | | :--- | :--- | :--- | | | Normal operation | System ready. | | Slow Blink Green | Standby / No run signal | Missing interlock or run command input. | | Fast Blink Red | Sensor signal loss | The sensor is disconnected, dirty, or failed. | | Alternating Red/Green | Actuator overload | Motor draw exceeds 4 amps; mechanical bind or short circuit. | | Solid Red | Internal processor fault | Replace board or flash firmware. |
Hold the web material in the sensor gap. Press and hold the "Calibrate" button on the sensor amplifier (or the CSP-01 board if equipped) for 5 seconds. The LED will flash twice, indicating the "web present" value is stored. Fife Csp-01 Manual
Remove the web. Press and hold the calibration button again for 5 seconds. The LED will flash three times, storing the "no web" value. | LED Status (Red/Green) | Error Description |